USA ▼
Rental > EM2010

Rental of EM2010 Environmental Noise Monitor

environmental noise monitor rental

The EM2010 is a Type 1 environmental noise monitor for the medium and long term monitoring of sound levels. It is quick and easy to install, just needing power and a connection to the cell network.

Applications

  • Environmental Noise Monitor
  • Weatherproof
  • Audio Recording

Main Features

  • Web Based Reporting
  • Cell Phone Network Connection
  • SMS and Email Alerts

Rental Kit Includes

  • EM2010 Environmental Noise Processor
  • Outdoor Microphone
  • Weatherproof Case
<
>
M
T
W
T
F
S
S
Rental Period:
$

Overview

The EM2010 Environmental Noise Monitor consists of an Outdoor Microphone, an acoustic processing unit, and a power supply. It can be connected up in minutes - just connect the microphone and power supply to the processor and away it goes. The unit will automatically measure the periodic Leq and L90 along with many other parameters, storing the results internally and uploading them to the web server every five minutes. The EM2010 can be set to record the audio when preset conditions are met. Listening to the audio is the best way to identify the source of high noise levels.

The noise reports are viewed by logging in to a web site and selecting the days of interest. The results can be viewed in a tabular or graphical format, or you can download them to Excel (or similar spreadsheet program) and create your own reports.

Environmental Noise Surveys

The EM2010 is for monitoring environmental noise, generally around industrial areas and in communities. It is ideal for any noise monitoring applications that demand a unit that meets IEC 61672 Class 1 or ANSI S1.4 Type 1 and requires access to the noise measurements through a standard web browser.

  • Environmental noise surveys
  • Boundary noise monitoring
  • Mixed commercial and residential sites
  • Construction and demolition sites
  • Positive noise source identification with audio recording

Setting Up

The EM2010 Noise Monitor comes with the GSM link (connection to cell network) already operating. All you need to do is position the monitor and apply power. The whole kit, including the microphone, is protected against poor weather conditions and rain.

Reporting

As the noise monitor uploads all its measurements to a web server, you just need a standard web browser and access to the Internet to view the reports.

StandardsIEC61672 Class 1, ANSI S1.4 Type 1
Frequency WeightingA and C Weighting
Frequency Range20 Hz to 20 kHz
Dynamic Range33 to 121 dB
ParametersLeq, L5, L10, L50, L90, L95, Lmax
Periods1, 5, 10, 15 or 30 minutes
Data Storage1 year with 5 minute logging
Web Storage2 GB included
CommunicationsHSPA / UMTS (3G), WiFi 802.11 b/g